Part Number: SRCOOL60KCW
This Model has been retired and has not been replaced. An Owner's Manual and other information for the SRCOOL60KCW is available on the model support page
Overview
A built-in controller detects and manages data center temperatures, automatically adjusts cooling levels and supports two automatic control modes: intelligent control mode and PID control mode. The user-friendly LED and LCD interface provides at-a-glance setting, monitoring and access to system configuration and status.
An alarm system notifies you in case of abnormal conditions, including high condensation, high or low temperature or humidity, and full drain pan. The SRCOOL60KCW In-Row Rack Air Conditioner also monitors heat load temperature via remote sensors and informs you of any water leakage. Hot-swappable multi-speed fans provide variable CFM based on room conditions.
The doors and side panels lock securely to help prevent damage, tampering or theft. A preinstalled TLNETCARD web management accessory lets you monitor temperatures, receive alerts, review logs and control settings from anywhere 24/7 via Ethernet network.
Features
- Pulls unconditioned air through rear of the unit, cools it with chilled water and releases cold air through front
- Lowers energy costs
- Lengthens equipment lifespan
- Row-based unit integrates with data centers and can be positioned adjacent to heat loads
Intelligent Temperature Control
- Detects and manages data center temperature
- Automatically adjusts cool air output
- Dual auto control modes: intelligent control mode and PID control mode
User-Friendly Interface
- Easy-to-read LEDs indicate power, standby, alarm and fault information at a glance
- LCD screen provides access to power, status, setting and administrator controls
3-Way Ball Valve
- Automatically closes within 15 sec. of abnormal power interruption to prevent water from flowing into the coil and creating condensation
Condensed Water Pump
- Automatically drains condensed water and detects water pan’s respective level to avoid leakage
Optional Upper Piping Configuration
- Supports upper and lower (with optional SRCOOL60KTP, sold separately) piping for flexible configuration
Alarm and Detection Systems
- Remote temperature sensors accurately monitor heat load temperature
- Optional water leakage detector configurable up to 50 m (164 ft.)
- 2 output and 2 input dry contacts for fire, smoke and system alarms
- Detects abnormal conditions and reports via buzzer, external dry contact device or Ethernet
Designed for Security and Long Life
- Doors and side panels lock securely to help prevent damage, tampering or theft
- Insulated side panels isolate unit from external temperature variations
- Multi-speed hot-swappable fans provide variable CFM based on room conditions
Built-In Rolling Casters
- Heavy-duty casters allow you to easily roll the unit where needed
Advanced Network Monitoring
- Built-in TLNETCARD lets you monitor temperatures, receive alerts, review logs and control settings 24/7 via Ethernet
- Optional SRCOOL60KRT or SRCOOL60KRTH remote sensors (sold separately) accurately monitor heat loads
Package Includes
- SRCOOL60KCW SmartRack In-Row Precision Server Rack Cooling Unit - 60 kW, 208–230V, 50/60 Hz, Chilled Water Type
- (2) 4-pin terminal blocks
- 3-pin terminal block
- RJ45 to DB9 cable
- (2) Cable glands
- (2) Communications wiring duct cover plates
- Power supply cover plate
- Hex wrench, 2.8 mm
- (3) Cable ties
- (2) Keys
- Owner’s manual
Specifications
OVERVIEW
UPC Code | 037332190307 |
INPUT
Electrical Consumption (Max) | 2410 Watt Max |
Nominal Input Voltage(s) Supported | 208V AC; 230V AC |
Maximum Input Amps | 12 |
Input Connection Type | 5 POLE TERMINAL BLOCK, 300 VOLTS, 30 AMPS |
Input Frequency | 50/60 Hz |
COOLING
Airflow | 4400 CFM |
Cooling Type | Active |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LEDs | Multi-line LCD control panel |
PHYSICAL
Color | Black |
Material of Construction | Aluminium, Steel |
Shipping Dimensions (hwd / in.) | 86.02 x 17.00 x 50.40 |
Shipping Weight (lbs.) | 555.57 |
Unit Dimensions (hwd / in.) | 78.740 x 11.810 x 42.910 |
Unit Weight (lbs.) | 416.67 |
ENVIRONMENTAL
Storage Temperature Range | -15 DEG C to 65 DEG C |
Operating Elevation | 0 to 6561.8 |
Operating Temperature | 4 DEG C to 50 DEG C |
Operating Humidity Range | 5 to 95% |
Ambient Operation RH | 30% - 85% |
Chilled Water Flow Meter (LMP) | 10-80 LPM +/- 4%; 81-150 LPM +/- 2% |
Range of CHW Inlet Temperature (Celsius) | 5-22 DEG C; 5KG/CM2 |
Condensate Drain Pumps (L/HR) | 5 L/HR at 5MM head, (15 M horizontal) @ 60Hz; 5 L/HR at 4.8MM head, (15 M horizontal) @ 50Hz |
Condensate Water Drains | Drain pump drain tube, length 1.7M, I.D. 3/8", length cut out of cabinet, 1M |
Primary Fan Filters | Aluminum (washable), MERV 1, ASHRAE 52.2 |
COMMUNICATIONS
SNMP Compatibility | TLNETCARD |
Hotkey | Press UP+DOWN and hold 3 seconds to enter auto mode |
Alarm Events | The following will trigger a warning (yellow LED): Filter abnormal, condensate level high, inner comminication abnormal, temp/humidity sensor temp high/low, inlet water temp high/low, chiller flow rate high/low, T/RH sensor humidity high/low, NTC temp high/low, run over hours, cooling capacity abnormal |
Fault Events | The following will trigger a fault (red LED): Condensate overflow, leak, fire, smoke, T/RH sensor abnormal, NTC abnormal, RTD sensor abnormal, flow meter abnormal, fan abnormal, ball valve abnormal, drain pan full |
Input Dry Contact Ports | 2 contacts (fire and smoke alarm inputs), 3 second delay to trigger |
Output Dry Contact Ports | 2 contacts |
Systems & Sensors Information | Supply air temp and humidity (SHT15), return air temp and humidity (SHT15), rack inlet temp (NTC) (optional), chilled water flow rate, chilled water inlet and outlet temp, ball valve position rate/feedback, filter clogged (pressure switch) |
Controller Area Network (CAN bus) | Supported |
Communications Interface | DB9 Serial; RS485 (+,-, G) |
FEATURES & SPECIFICATIONS
Sound Level (Noise) | 88 DBA @ 4400 CFM @ 1 METER |
Fans (Type/Quantity) | 54V, 5800 RPM, 825 CFM, Brushless fan, hot-swappable (8) |
MECHANICAL
Chilled Water Outlet | 1 INT, PT/Female |
Chilled Water Inlets | 1 INCH, PT/Female |
OPERATION
Operation Mode | Stand-by, Auto, Installation, Force, Manual |
Supply Air Temperature (Celsius) | 18-27 deg. C (limited by heating load) |
Glycol Correction Details | Return air temp: 29.4 deg. C DB; 18.1 deg. C WB; Air volume: 4930 M3/H; Temp difference of chilled water 7.2 deg. C; Chilled water flow rate: 62 LPM; Max solution not to exceed 50% |
Applied Containment Types | Close/Open |
Ball Valve Controls | PID Controller, fuzzy logic support |
Fan Controls | By setting return air max flow T, Min flow T, Fan step setting for proportional control |
Force Modes | Three-way valve fully opens, fans at full speed, stand by LED flashing |
Installation Modes | Three-way valve fully opens, fans at minimum speed, main LED flashing |
Manual Modes | Fan speed, ball valve open/closed, back light, buzzer, alarms, chilled pump, LEDs, drain pump, main and stand-by LEDs on solid |
Power Redundancies | Dual input with two rectifiers |
System Type Selections | Open type (open type initial fan speed is 50%), closed type (closed type initial fan speed is 30%) |
Temperature Unit Selections | Deg. C; Deg. F (default is Deg. C) |
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) | 1-year limited warranty |
Questions & Answers
Documents & Downloads
Design Resources
Product Literature
- Cooling Solutions Brochure (English)
- SRCOOL60KCW Range of CHW Flow Rate (LPM)/Water Side Pressure Drop (kPa)
- SRCOOL60KCW Altitude Correction Factor
- SRCOOL60KCW Glycol Correction
- SRCOOL60KCW Nominal Cooling Capacity
- Close-Coupled Cooling Solutions Product Announcement Flyer (English)
- Rack Models & Specifications Brochure (English)
- Stack the Rack Data Center Solutions Flyer (English)
Declarations of Conformity
Product Videos
- Why Rack Cooling Efficiency Matters
https://tripplite.eaton.com/video/why-rack-cooling-efficiency-matters/815511
Product Images